The 6xxxyyyy system reference codes are virtual optical reference codes.
Look for the rightmost 4 characters (yyyy in 6xxxyyyy) in the error code; this is the reference code. Find the reference code in Table 1.
|
||
---|---|---|
6xxxyyyy Error Codes | Description | Action |
632Byyyy codes are Network File System (NFS) virtual optical SRCs | ||
632BCFC1 | A virtual optical device cannot access the file containing the list of volumes. | On this partition and on the Network File System server, verify that the proper file is specified and that the proper authority is granted. |
632BCFC2 | A non-recoverable error was detected while reading the list of volumes. | Resolve any errors on the Network File System server. |
632BCFC3 | The data in the list of volumes is not valid. | On the Network File System server, verify that the proper file is specified, that all files are entered correctly, that there are no blank lines, and that the character set used is valid. |
632BCFC4 | A virtual optical device cannot access the file containing the specified optical volume. | On the Network File System server, verify that the proper file is specified in the list of volumes, and that the proper authority is granted. |
632BCFC5 | A non-recoverable error was detected while reading a virtual optical volume. | Resolve any errors on the Network File System server. |
632BCFC6 | The file specified does not contain data that can be processed as a virtual optical volume. | On the Network File System server, verify that all the files specified in the list of optical volumes are correct. |
632BCFC7 | A virtual optical device detected an error reported by the Network File System server that cannot be recovered. | Resolve any errors on the Network File System server. |
632BCFC8 | A virtual optical device encountered a non-recoverable error. | Install any available operating system updates. |
632Cyyyy codes are virtual optical SRCs | ||
632CC000 | Informational system log entry only. | No corrective action is required. |
632CC002 | self configuring SCSI device (SCSD) selection or reselection timeout occurred. | Refer to the hosting partition for problem analysis. |
632CC010 | Undefined sense key returned by device. | Refer to the hosting partition for problem analysis. |
632CC020 | Configuration error. | Refer to the hosting partition for problem analysis. |
632CC100 | SCSD bus error occurred. | Refer to the hosting partition for problem analysis. |
632CC110 | SCSD command timeout occurred. | Refer to the hosting partition for problem analysis. |
632CC210 | Informational system log entry only. | No corrective action is required. |
632CC300 | Media or device error occurred. | Refer to the hosting partition for problem analysis. |
632CC301 | Media or device error occurred. | Refer to the hosting partition for problem analysis. |
632CC302 | Media or device error occurred. | Refer to the hosting partition for problem analysis. |
632CC303 | Media has an unknown format. | No corrective action is required. |
632CC333 | Incompatible media. |
|
632CC400 | Physical link error detected by device. | Refer to the hosting partition for problem analysis. |
632CC402 | An internal program error occurred. | Install any available operating system updates. |
632CCFF2 | Informational system log entry only. | No corrective action is required. |
632CCFF4 | Internal device error occurred. | Refer to the hosting partition for problem analysis. |
632CCFF6 | Informational system log entry only. | No corrective action is required. |
632CCFF7 | Informational system log entry only. | No corrective action is required. |
632CCFFE | Informational system log entry only. | No corrective action is required. |
632CFF3D | Informational system log entry only. | No corrective action is required. |
632CFF6D | Informational system log entry only. | No corrective action is required. |