6xxxyyyy SRCs

The 6xxxyyyy system reference codes are virtual optical reference codes.

Look for the rightmost 4 characters (yyyy in 6xxxyyyy) in the error code; this is the reference code. Find the reference code in Table 1.

Table 1. 6xxxyyyy SRCs
  • Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. If an action solves the problem, then you can stop performing the remaining actions.
  • See Parts listing, type 7891 to determine which components are CRUs and which components are FRUs.
6xxxyyyy Error Codes Description Action
632Byyyy codes are Network File System (NFS) virtual optical SRCs
632BCFC1 A virtual optical device cannot access the file containing the list of volumes. On this partition and on the Network File System server, verify that the proper file is specified and that the proper authority is granted.
632BCFC2 A non-recoverable error was detected while reading the list of volumes. Resolve any errors on the Network File System server.
632BCFC3 The data in the list of volumes is not valid. On the Network File System server, verify that the proper file is specified, that all files are entered correctly, that there are no blank lines, and that the character set used is valid.
632BCFC4 A virtual optical device cannot access the file containing the specified optical volume. On the Network File System server, verify that the proper file is specified in the list of volumes, and that the proper authority is granted.
632BCFC5 A non-recoverable error was detected while reading a virtual optical volume. Resolve any errors on the Network File System server.
632BCFC6 The file specified does not contain data that can be processed as a virtual optical volume. On the Network File System server, verify that all the files specified in the list of optical volumes are correct.
632BCFC7 A virtual optical device detected an error reported by the Network File System server that cannot be recovered. Resolve any errors on the Network File System server.
632BCFC8 A virtual optical device encountered a non-recoverable error. Install any available operating system updates.
632Cyyyy codes are virtual optical SRCs
632CC000 Informational system log entry only. No corrective action is required.
632CC002 self configuring SCSI device (SCSD) selection or reselection timeout occurred. Refer to the hosting partition for problem analysis.
632CC010 Undefined sense key returned by device. Refer to the hosting partition for problem analysis.
632CC020 Configuration error. Refer to the hosting partition for problem analysis.
632CC100 SCSD bus error occurred. Refer to the hosting partition for problem analysis.
632CC110 SCSD command timeout occurred. Refer to the hosting partition for problem analysis.
632CC210 Informational system log entry only. No corrective action is required.
632CC300 Media or device error occurred. Refer to the hosting partition for problem analysis.
632CC301 Media or device error occurred. Refer to the hosting partition for problem analysis.
632CC302 Media or device error occurred. Refer to the hosting partition for problem analysis.
632CC303 Media has an unknown format. No corrective action is required.
632CC333 Incompatible media.
  1. Verify that the disk has a supported format.
  2. If the format is supported, clean the disk and attempt the failing operation again.
  3. If the operation fails again with the same system reference code, ask your media source for a replacement disk.
632CC400 Physical link error detected by device. Refer to the hosting partition for problem analysis.
632CC402 An internal program error occurred. Install any available operating system updates.
632CCFF2 Informational system log entry only. No corrective action is required.
632CCFF4 Internal device error occurred. Refer to the hosting partition for problem analysis.
632CCFF6 Informational system log entry only. No corrective action is required.
632CCFF7 Informational system log entry only. No corrective action is required.
632CCFFE Informational system log entry only. No corrective action is required.
632CFF3D Informational system log entry only. No corrective action is required.
632CFF6D Informational system log entry only. No corrective action is required.