AAxx attention codes provide information about the next target state for the platform firmware. These codes might indicate that you need to perform an action.
Table 1 describes the partition firmware codes that might be displayed if the POST detects a problem. Each message description includes a suggested action to correct the problem.
|
||
---|---|---|
Attention code | Description | Action |
AA00E1A8 | The system is booting to the open firmware prompt. | At the open firmware prompt, type dev /packages/gui obe and press Enter; then, type 1 to select SMS Menu. |
AA00E1A9 | The system is booting to the System Management Services (SMS) menus. |
|
AA00E1B0 | Waiting for the user to select the language and keyboard. The menu should be visible on the console. |
|
AA00E1B1 | Waiting for the user to accept or decline the license |
|
AA060007 | A keyboard was not found. | Verify that a keyboard is attached to the USB port that is assigned to the partition. |
AA06000B | The system or partition was not able to find an operating system on any of the devices in the boot list. |
|
AA06000C | The media in a device in the boot list was not bootable. |
|
AA06000D | The media in the device in the bootlist was not found under the I/O adapter specified by the bootlist. |
|
AA06000E | The adapter specified in the boot list is not present or is not functioning. |
|
AA060011 | The firmware did not find an operating system image and at least one hard disk in the boot list was not detected by the firmware. The firmware is retrying the entries in the boot list. | This might occur if a disk enclosure that contains
the boot disk is not fully initialized or if the boot disk belongs
to another partition. Verify that:
|
AA130013 | Bootable media is missing from a USB CD-ROM | Verify that a bootable CD is properly inserted in the CD or DVD drive and retry the boot operation. |
AA130014 | The media in a USB CD-ROM has changed. |
|
AA170210 | Setenv/$setenv parameter error - the name contains a null character. |
|
AA170211 | Setenv/$setenv parameter error - the value contains a null character. |
|
AA190001 | The hypervisor function to get or set the time-of-day clock reported an error. |
|
AA260001 | Enter the Type Model Number (Must be 8 characters) | Enter the machine type and model of the blade server at the prompt. |
AA260002 | Enter the Serial Number (Must be 7 characters) | Enter the serial number of the blade server at the prompt. |
AA260003 | Enter System Unique ID (Must be 12 characters) | Enter the system unique ID number at the prompt. |
AA260004 | Enter WorldWide Port Number (Must be 12 characters) | Enter the worldwide port number of the blade server at the prompt. |
AA260005 | Enter Brand (Must be 2 characters) | Enter the brand number of the blade server at the prompt. |