Core electronics: 64-bit 2 x POWER7® processors (12S technology)
PS703 single-wide
model: - 16-way single-wide blade: 2 socket 8-core at 2.4 GHz
- 16 very low profile (VLP) DIMM slots. Maximum capacity is 128
GB. Supports
4 GB DDR3 and 8 GB DDR3 at 1066 MHz
PS704 double-wide
model: - 32-way double-wide: 2x8-way base with 2x8-way expansion
- 32 very low profile (VLP) DIMM slots. Maximum capacity is 256
GB. Supports
4 GB DDR3 and 8 GB DDR3 at 1066 MHz
P7IOC I/O hub
On-board, integrated features: - FSP1 Service Processor - IPMI, SOL
- Two 1 Gb Ethernet ports using 5709S Ethernet controller (two on PS703 ,
four on PS704)
- SAS controller
- USB 2.0
- 1 Serial over LAN (SOL) console using BMC Ethernet port
Local storage:
- PS703 :
Maximum of one SAS 2.5 in. hard disk drive (HDD) or maximum of two
SATA 1.8 in. solid-state drives (SSDs) or none
- PS704:
- Maximum of two SAS 2.5 in. HDDs or maximum of four SATA 1.8 in.
SSDs or none
- Valid options:
- None
- 1 HDD
- 2 HDDs
- 1 HDD and 1 SSD
- 1 HDD and 2 SSDs
- 2 SSDs, 3 SSDs, or 4 SSDs
- SSDs are 200 GB
- HDDs are 300 GB and 600 GB
- RAID functions supported
|
Daughter card I/O options:
- in the PS703 :
- Supports one expansion card (CIOv)
- Supports one CFFh expansion card (combination form factor horizontal
high-speed data card)
- Supports one SAS passthrough using CIOv
- PS704:
- Supports two expansion cards (CIOv)
- Supports two CFFh expansion cards
- Supports up to two SAS passthroughs using CIOv
Integrated functions: - RS-485 interface for communication with the management module
- Automatic server restart (ASR)
- SOL through service processor
- Two Universal Serial Buses (USB 2.0) on base system board for
communication with removable-media drives
- Optical media available by shared chassis feature
Environment: - Air temperature:
- Blade server with power on: 10° - 35°C (50° - 95°F). Altitude:
0 - 914 m (3000 ft)
- Blade server with power on: 10° - 32°C (50° - 90°F). Altitude:
914 m - 2133 m (3000 ft - 7000 ft)
- Blade server with power off: -40° - 60°C (-40° - 140°F)
- Humidity:
- Blade server with power on: 8% - 80%
- Blade server with power off: 8% - 80%
PS703 or PS704 size: - Height: 24.5 cm (9.7 in.)
- Depth: 44.6 cm (17.6 in.)
- PS703: Width: 30 mm (1.14 in.) PS704: 60 mm (2.28 in.)
|
Systems management:- Supported by BladeCenter chassis
management module
- Front panel LEDs
- IBM Director
- Hardware Management Console (HMC)
- Integrated Virtualization Manager (IVM)
- Energy scale thermal management for power management, power oversubscription
(throttling), and environmental sensing
- Active Energy Manager
- Concurrent Code Update via Director Update Manager, Inventory
Collection, Multiple VIOS, and PowerVM® Enterprise
Virtualization support for:
PowerVM Standard Edition hardware feature,
which provides the Integrated Virtualization Manager, Virtual I/O
Server, and IBM Systems Director Management
Console (SDMC).
No HMC support
Reliability and
service features: - Dual alternating current power supply
- BladeCenter chassis
redundant and hot-plug power and cooling modules
- Boot-time processor deallocation
- Blade server hot plug
- Customer setup and expansion
- Automatic reboot on power loss
- Internal and ambient temperature monitors
- ECC, chipkill memory
- System management alerts
- Light path diagnostics
- Electronic Service Agent™ call home capability
Electrical input: 12 V DC
|