Symptom |
Action |
The blade server will not boot or a checkpoint
or firmware error code is logged in the management-module event log
(the startup microprocessor is not working correctly) |
- If a checkpoint or firmware error was logged in the Advanced Management
Module event log, correct that error.
- If no error was logged, restart the blade server and check the
management module event log again for error codes.
- Replace the system-board
|