Complete this procedure to remove a combination-form-factor
(CFFh) expansion card from a PS703
blade server, or from either the base unit or the expansion unit of
a PS704 blade server.
Figure 1. Removing a
combination-form-factor expansion card
- Read
the Safety topic and the Installation guidelines.
- Shut down the operating system,
turn off the blade server, and remove the blade server from the BladeCenter® unit. See Removing the blade server from a BladeCenter unit.
- Open and remove the blade
server
cover. See Removing the blade server cover.
- Remove the horizontal (CFFh) CFFe expansion
card 2 .
- Pull
all the way up on the cam lever 4 until
it disengages the card from the high-speed PCI Express® (PCIe) connector.
- Gently pivot the card up and out of the expansion card
standoffs 3 on the system board.
- Lift the card out of the blade server.
- Optional: Reattach the plastic
cover 1 for
the PCIe connector, if it is available.
- If you are instructed to
return
the expansion card, follow all packaging instructions, and use any
packaging materials for shipping that are supplied to you.