You can remove this tier 2 CRU yourself or request IBM® to remove it, at no additional
charge, under the type of warranty service that is designated for
the blade server. Remove the management card to replace the card or
to reuse the card in a new system board and chassis assembly.
Attention: Replacing the management card and the
system board at the same time might result in the loss of vital product
data (VPD) and information concerning the number of active processor
cores. If the management card and system board must both be replaced,
replace them one at a time. For further assistance, contact your next
level of support.
To remove the management card, which is shown by
1 in
Figure 1, complete
the following steps:
- Read
the Safety topic and the Installation guidelines.
- Turn off the blade server and remove the blade server from
the BladeCenter® unit.
See Removing the blade server from a BladeCenter unit.
- Carefully lay the blade server
on a flat, static-protective surface, with the cover side up.
- Open and remove the blade
server
cover. See Removing the blade server cover.
- Grasp the management card and pull it vertically out of
unit to disengage the connectors.
Figure 1. Removing the management card
- If you are instructed to return the management card, follow
all packaging instructions, and use any packaging materials for shipping
that are supplied to you.
- Replace the management card. See Installing the tier 2 management card.