Use this worksheet to describe each blade server and workstation blade that you plan to install in the BladeCenter S system. Fill out one worksheet for each blade server that you will install.
Workstation blade model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
Workstation blade |
1 | Workstation blade with Intel™ Xeon processor | Base |
Video graphics adapter | 1 |
☐ NVIDIA Quadro |
Base |
Memory slots 1 and 2 | 2 |
☐ 512 MB |
Base |
Memory slots 3 and 4 | 2 |
☐ 512 MB |
Optional |
SATA internal hard disk drive | 1 |
☐ 60 GB |
Optional |
Blade server model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
Blade server |
1 | Blade server with Intel™ Xeon processor | Base |
Memory slot 1 | 1 |
☐ 512 MB |
Base |
Memory slots 2–6 | 5 |
☐ 512 MB |
Optional |
cKVM feature | ☐ cKVM card | Optional | |
Internal hard disk drives | 2 |
☐ 15.8 GB Solid State |
Optional |
I/O Expansion cards | 1 |
☐ Ethernet
Note: Make sure that the type of switch modules used
in I/O bays 3 and 4 match the type of I/O expansion cards that you
choose.
|
Optional |
PCI I/O Expansion Unit | 1 | PCI I/O Expansion Unit 3e | Optional |
Blade server model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
Blade server |
1 | Blade server with Intel™ Xeon processor | Base with either two 256 or 512 MB memories |
Second processor | 1 | Xeon DP | Optional |
Memory slots 1 and 2 | 2 |
☐ 256 MB |
Base |
Optional memory choices for slots 3 and 4 | 2 |
☐ 512 MB |
Two 256 or 512 MB base memory |
EIDE hard disk drives | 1 or 2 | 40 GB ATA 100; 5400 RPM | Optional (not supported for NEBS environment) |
IDE Flash disk drive | 1 or 2 |
☐ 1 GB |
Optional |
I/O Expansion option | 1 |
☐ Ethernet |
Optional |
SCSI Storage Expansion option | 1 | Supports two additional hot-swapped SCSI hard disk drives | Optional |
SCSI hard disk drive | 1 or 2 | Optional | |
PCI I/O Expansion option | 1 | Supports two PCI-X adapters | Optional |
PCI-X adapter 1 | Optional | ||
PCI-X adapter 2 | Optional |
Blade server model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
Blade server |
1 | Blade server with Intel™ Xeon processor | Base |
Second processor | 1 | Xeon processor | Optional |
Memory slots 1 and 2 | 2 |
☐ 512 MB |
Base |
Optional memory choices slots 3 and 4 | 2 |
☐ 512 MB |
Optional |
cKVM feature | ☐ cKVM card | Optional | |
Internal hard disk drive | 2 |
☐ 36 GB SAS |
Optional |
Storage and I/O Expansion blade | 1 |
☐ PCI I/O Expansion |
Optional |
I/O Expansion option | 1 |
☐ Ethernet |
Optional |
Blade server model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
Blade server |
1 | Blade server with Intel™ Xeon processor | Base |
Second processor | 1 | Xeon processor | Optional |
Memory slots 1 and 2 | 2 |
☐ 512 MB ☐ 2 GB |
Base |
Optional memory choices slots 3 and 4 | 2 |
☐ 512 MB ☐ 2 GB |
Optional |
Optional Memory slots 5 and 6 | 2 |
☐ 512 MB ☐ 2 GB |
Optional |
Optional memory choices slots 7 and 8 | 2 |
☐ 512 MB ☐ 2 GB |
Optional |
cKVM feature | ☐ cKVM card | Optional | |
Modular flash drive (USB compact flash) | 1 |
☐ 4 GB ☐ 8 GB |
Optional |
Internal hard disk drive | 1 |
☐ 36 GB SAS |
Optional |
Storage and I/O Expansion blade | 1 |
☐ PCI I/O Expansion |
Optional |
I/O Expansion option | 1 |
☐ Ethernet |
Optional |
Blade server model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
8844 blade server |
1 | Two single-core, 64-bit, IBM PowerPC® 970MP microprocessors (2.7 GHz in BladeCenter H unit, 2.6 GHz in other BladeCenter units) or two dual-core, 64-bit, IBM PowerPC 970MP microprocessors (2.5 GHz in BladeCenter H unit, 2.3 GHz in other BladeCenter units) | Base with two 1 GB dual inline memory modules (DIMMs) standard with 2-core (two single-core processors); two 2 GB DIMMs with 4-core (two dual-core processors). |
Memory slots 1 and 3. Select a memory size. (Optional) | 2 |
☐ 512 MB |
Optional; Second pair of DIMMs must match speed of first pair of DIMMs, but can vary in size, type, technology, and physical design. |
Optional memory choices for slots 2 and 4 (Base) | 2 |
☐ 1 GB |
Each DIMM in this pair must be the same size, speed, type, technology, and physical design. |
Serial Attached SCSI (SAS) hard disk drive | 1 or 2 | 73.4 GB SAS 10 K RPM | Optional; Support for two internal small-form-factor SAS drives; Optional 146 GB SFF SAS drive available |
Networking expansion card options: SFF Gb Ethernet |
1 |
☐ Ethernet |
Optional; 1 GB Ethernet Dual Port Expansion Card, CFF/PCIX Combo 4 GB Fibre Channel/1GB E'Net Expansion Card, CFF/PCIE, (QLogic) Myricom Myrinet Cluster Expansion Card, LFF/PCIX (InfiniBand) 4X InfiniBand Dual Port Expansion Card, SFF/PCIE, (Cisco) |
SCSI storage expansion option | 1 | Supports two additional hot-swapped SCSI hard disk drives | Optional; QLogic iSCSI Expansion Card for IBM eServer BladeCenter |
Fibre Channel storage expansion card options: CFFv controller |
1 | Supports two adapters | Optional; QLogic 4Gb SFF Fibre Channel Expansion Card for IBM eServer BladeCenter QLogic 4Gb Fibre Channel Expansion Card (CFFv) for IBM BladeCenter 4 GB Fibre Channel Dual Port Expansion Card, SFF/PCIX (Emulex) |
Blade server model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
8844 blade server |
1 | Two single-core, 64-bit, IBM PowerPC® 970MP microprocessors (2.7 GHz in BladeCenter H unit, 2.6 GHz in other BladeCenter units) or two dual-core, 64-bit, IBM PowerPC 970MP microprocessors (2.5 GHz in BladeCenter H unit, 2.3 GHz in other BladeCenter units) | Base with two 1 GB dual inline memory modules (DIMMs) standard with 2-core (two single-core processors); two 2 GB DIMMs with 4-core (two dual-core processors). |
Memory slots 1 and 3. Select a memory size. (Optional) | 2 |
☐ 512 MB |
Optional; Second pair of DIMMs must match speed of first pair of DIMMs, but can vary in size, type, technology, and physical design. |
Optional memory choices for slots 2 and 4 (Base) | 2 |
☐ 1 GB |
Each DIMM in this pair must be the same size, speed, type, technology, and physical design. |
Serial Attached SCSI (SAS) hard disk drive | 1 or 2 | 73.4 GB SAS 10 K RPM | Optional; Support for two internal small-form-factor SAS drives; Optional 146 GB SFF SAS drive available |
Networking expansion card options: SFF Gb Ethernet |
1 |
☐ Ethernet |
Optional; 1 GB Ethernet Dual Port Expansion Card, CFF/PCIX Combo 4 GB Fibre Channel/1GB E'Net Expansion Card, CFF/PCIE, (QLogic) Myricom Myrinet Cluster Expansion Card, LFF/PCIX (InfiniBand) 4X InfiniBand Dual Port Expansion Card, SFF/PCIE, (Cisco) |
SCSI storage expansion option | 1 | Supports two additional hot-swapped SCSI hard disk drives | Optional; QLogic iSCSI Expansion Card for IBM eServer BladeCenter |
Fibre Channel storage expansion card options: CFFv controller |
1 | Supports two adapters | Optional; QLogic 4Gb SFF Fibre Channel Expansion Card for IBM eServer BladeCenter QLogic 4Gb Fibre Channel Expansion Card (CFFv) for IBM BladeCenter 4 GB Fibre Channel Dual Port Expansion Card, SFF/PCIX (Emulex) |
Blade server model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
8844 blade server |
1 | Two single-core, 64-bit, IBM PowerPC® 970MP microprocessors (2.7 GHz in BladeCenter H unit, 2.6 GHz in other BladeCenter units) or two dual-core, 64-bit, IBM PowerPC 970MP microprocessors (2.5 GHz in BladeCenter H unit, 2.3 GHz in other BladeCenter units) | Base with two 1 GB dual inline memory modules (DIMMs) standard with 2-core (two single-core processors); two 2 GB DIMMs with 4-core (two dual-core processors). |
Memory slots 1 and 3. Select a memory size. (Optional) | 2 |
☐ 512 MB |
Optional; Second pair of DIMMs must match speed of first pair of DIMMs, but can vary in size, type, technology, and physical design. |
Optional memory choices for slots 2 and 4 (Base) | 2 |
☐ 1 GB |
Each DIMM in this pair must be the same size, speed, type, technology, and physical design. |
Serial Attached SCSI (SAS) hard disk drive | 1 or 2 | 73.4 GB SAS 10 K RPM | Optional; Support for two internal small-form-factor SAS drives; Optional 146 GB SFF SAS drive available |
Networking expansion card options: SFF Gb Ethernet |
1 |
☐ Ethernet |
Optional; 1 GB Ethernet Dual Port Expansion Card, CFF/PCIX Combo 4 GB Fibre Channel/1GB E'Net Expansion Card, CFF/PCIE, (QLogic) Myricom Myrinet Cluster Expansion Card, LFF/PCIX (InfiniBand) 4X InfiniBand Dual Port Expansion Card, SFF/PCIE, (Cisco) |
SCSI storage expansion option | 1 | Supports two additional hot-swapped SCSI hard disk drives | Optional; QLogic iSCSI Expansion Card for IBM eServer BladeCenter |
Fibre Channel storage expansion card options: CFFv controller |
1 | Supports two adapters | Optional; QLogic 4Gb SFF Fibre Channel Expansion Card for IBM eServer BladeCenter QLogic 4Gb Fibre Channel Expansion Card (CFFv) for IBM BladeCenter 4 GB Fibre Channel Dual Port Expansion Card, SFF/PCIX (Emulex) |
Blade server model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
Blade server |
1 | Blade server with AMD Opteron processor | Base |
Second processor | 1 | AMD Opteron processor | Optional |
Memory slots 1 and 2 | 2 |
☐ 512 MB |
Base |
Optional memory choices slots 3 and 4 | 2 |
☐ 512 MB |
Optional |
SCSI internal hard disk drive | 1 or 2 |
☐ 36 GB |
Optional |
I/O Expansion option | 1 |
☐ Ethernet |
Optional |
Blade server model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
Blade server |
1 | Blade server with AMD Opteron processor | Base |
Second processor | 1 | AMD Opteron processor | Optional |
Memory slots 1 and 2 | 2 |
☐ 512 MB ☐ 2 GB |
Base |
Optional memory choices slots 3 and 4 | 2 |
☐ 512 MB ☐ 2 GB |
Optional |
Memory slots 5 and 6 | 2 |
☐ 512 MB ☐ 2 GB |
Optional |
Optional memory choices slots 7 and 8 | 2 |
☐ 512 MB ☐ 2 GB |
Optional |
cKVM feature | ☐ cKVM card | Optional | |
Internal hard disk drive | 1 |
☐ 36 GB SAS |
Optional |
Storage and I/O Expansion blade | 1 |
☐ PCI I/O Expansion |
Optional |
I/O Expansion option | 1 |
☐ Ethernet |
Optional |
Blade server model: ________________ |
Connects to I/O module |
||
BladeCenter S chassis blade bay location 1 2 3 4 5 6 |
|||
Component | Quantity | Details | Base or optional feature |
Blade server |
1 | Blade server with AMD Opteron processor | Base |
Second processor | 1 | AMD Opteron processor | Optional |
Memory slots 1 and 2 | 2 |
☐ 512 MB ☐ 2 GB |
Base |
Optional memory choices slots 3 and 4 | 2 |
☐ 512 MB ☐ 2 GB |
Optional |
Memory slots 5 and 6 | 2 |
☐ 512 MB ☐ 2 GB |
Optional |
Optional memory choices slots 7 and 8 | 2 |
☐ 512 MB ☐ 2 GB |
Optional |
cKVM feature | ☐ cKVM card | Optional | |
Internal hard disk drive | 1 |
☐ 36 GB SAS |
Optional |
Storage and I/O Expansion blade | 1 |
☐ Multiprocessor |
Optional |
I/O Expansion option | 1 |
☐ Ethernet |
Optional |