If remote video displays, but local video does not, the
problem might be caused by the advanced management module.
Problem
Remote video sessions display normally,
but local video does not display.
Investigation
Perform these steps to resolve
the problem:
- Verify that the local monitor is powered on
and that it is operational.
- Reseat the advanced management module.
- Save the configuration for the advanced management module.
For
more information about saving and restoring previously saved configurations,
see the Advanced Management Module User's Guide.
- Reset the advanced management module to
the default configuration.
Important: Resetting the advanced management module will
shut down the external ports for all I/O modules, which will disrupt
all network connectivity. After the advanced management module resets
with the default configuration, it will attempt to obtain a DHCP address
before using the default IP address (192.168.70.125) and subnet mask
(255.255.255.0). Remove the Ethernet cable from the advanced management module if
you do not want it to attempt to obtain a DHCP address.
- Insert a paper clip into the pin hole on the back of the advanced management module.
- Push the paper clip in all the way and hold it for approximately
10 seconds. The advanced management module will
reset and the fan modules will run at full speed, which is clearly
audible.
- Remove the paper clip from the pin hole.
- If the local video now works, the problem is in the configuration
of the advanced management module.
- If the problem persists, call IBM .