To help ensure proper system cooling and system reliability, make
sure the following requirements are met.
- Each of the module bays on the front and rear of the BladeCenter S chassis has
either a module or a module bay filler installed in it.
- Each of the blade bays on the front of the BladeCenter S chassis has
either a blade server or a blade bay filler installed in it.
- Each of the disk storage module bays
has a disk storage module or disk storage module filler installed
in it. If a disk storage module is
installed, each of the drive bays has a hard disk drive or
a hard disk drive bay
filler installed in it.
- Each of the drive bays in a blade server storage expansion option has
either a hot-swap drive or a filler panel installed.
- You have followed the cabling instructions that come with optional adapters.
- Cables for the optional modules are routed correctly.
- A failed fan module is replaced as soon as possible.