Replacement of Tier 1 CRUs is your responsibility. If IBM® installs a
Tier 1 CRU at your request, you will be charged for the installation. However, IBM will
replace a Tier 2 CRU at your request for no additional charge.
Removing a bezel
To remove the bezel, press the release buttons and pull the bezel
away from the BladeCenter S chassis.
Installing a bezel
To install a bezel, align the bezel on the BladeCenter S chassis and
press the bezel into place until the release buttons lock.
Removing the media tray
You can remove the media tray while
the BladeCenter S system is
powered on. To remove it, open the release handles and slide the media
tray from the BladeCenter S chassis.
Installing the media tray
You can install the media tray while the BladeCenter S system is
powered on. To install it, slide it into the BladeCenter S chassis and
close the release handles.
Removing the DVD drive
To remove a DVD drive, open the media tray cover, pinch the DVD
retention release, and slide the DVD drive out of the media tray.
Installing the DVD drive
To install a DVD drive, slide the DVD drive into the media tray
until the DVD drive release locks. Then, close the media tray cover.
Removing the battery backup unit
To remove the battery backup unit, open the release handle
on the battery backup unit and slide the battery backup unit out of
the media tray.
Removing an advanced management module
You can remove the advanced management module while
the BladeCenter S system is
powered on. To remove it, disconnect all cables, open the release
handle, and slide the advanced management module out
of the BladeCenter S chassis.
Installing an advanced management module
You can install the advanced management module while
the BladeCenter S system is
powered on. To install it, open the release handle on the module and slide advanced management module into the advanced management module bay.
Removing a blade server
To remove a blade server, open the release handles and slide it
out of the BladeCenter S chassis.
Installing a blade server
To install a blade server in the front of the BladeCenter S chassis,
opening the release handles on the blade server, slide it into a blade server
bay, and close the release handles.
Removing a fan module
You can remove a fan module while the BladeCenter S system is
powered on. To remove it, grasp the fan handle and slide the fan module out
of the BladeCenter S chassis.
Installing a fan module
You can install a fan module while the BladeCenter S system is powered
on. To install it, slide the fan module into the fan module bay until the
fan handle locks.
Removing an I/O module
You can remove an I/O module while
the BladeCenter S system is
powered on. To remove it, disconnect all cables, open the release
handle, and slide the module out of the BladeCenter S chassis.
Installing an I/O module
You can install an I/O module while
the BladeCenter S system is
powered on. To install an I/O module, open the release handle, slide
the module into the I/O module bay of the BladeCenter S chassis,
and connect appropriate cables to the module.
Removing a power module
You can remove a power module while the BladeCenter S system is powered
on. To remove it, open the release handle and slide the power module out of
the power module bay.
Installing a power module
You can install a power module while the BladeCenter S system is
powered on. To install it, open the release handle, slide the power module
into the power module bay, and close the release handle.
Removing a serial pass-thru module
You can remove a serial pass-thru module while
the BladeCenter S system is
powered on. To remove it, disconnect all cables, open the release handle,
and slide the serial pass-thru module out
of the BladeCenter S chassis.
Installing a serial pass-thru module
You can install a serial pass-thru module while
the BladeCenter S system is
powered on. To install it in the serial pass-thru module bay,
open the release handle and slide the serial pass-thru module into
the serial pass-thru module module
bay.
Removing a disk storage module
You can remove a disk storage module while
the BladeCenter S system is
powered on. To remove it, remove the hard disk drives, open
the release handles on the disk storage module, and
slide the module out of the BladeCenter S chassis.
Installing a disk storage module
You can install a disk storage module while
the BladeCenter S system is
powered on. To install it, open the release handles on the disk storage module and
slide the disk storage module into
the disk storage module bay.
Then, you can install hard disk drives into
the disk storage module.