The removal of a System Power and Cooling (SPC) chassis (also called
a shuttle) should only be performed by a trained service technician.
-
Shut down the operating systems and turn off any blade servers
in the BladeCenter S chassis.
See the documentation that comes with the blade server for detailed instructions.
-
Disengage the blade servers from the front of the BladeCenter S chassis by
opening the release handles on all blade servers.
-
Disengage the media tray from the front of the BladeCenter S chassis by
opening the release handle.
-
Disengage the disk storage modulesfrom
the front of the BladeCenter S chassis by
opening the release handle on each disk storage module.
-
Disconnect the power from the BladeCenter S chassis.
-
Disconnect all cables from the modules in the rear of the BladeCenter S chassis.
-
Remove any of the following modules that are installed in the rear
of the BladeCenter S chassis:
-
Remove the left and right shipping brackets from the BladeCenter S chassis and
the rack, if they are installed.
-
Loosen the captive thumbscrews on the SPC chassis release handles.
-
Open the release handles on the shuttle (rotate the handles up)
to disengage the SPC chassis from the BladeCenter S chassis.
-
Using the handles, pull the SPC chassis out until it stops (approximately
half way out).
-
While supporting the shuttle with your hands, press the release
latches on each side, and pull the SPC chassis out of the BladeCenter S chassis.
-
If you are replacing the SPC chassis with a new SPC chassis, remove
the midplane (see Removing the midplane)
and any remaining module fillers for installation on the replacement part.