This topic lists error messages for the fuelg command.
See Common errors for a list of error messages that apply to all commands.
Error message | Definition |
---|---|
-am cannot be enabled while -e is set to nebs. | The user attempts to enable the acoustic mode while the environment is set to nebs. |
-ps and -dps cannot be enabled at the same time. | The user attempts to enable -ps and idps at the same time. |
A power module failure in domain domain_number can
result in an immediate shutdown. where domain_number identifies the power domain. |
A power module fails and the domain in which it is installed loses redundancy. The BladeCenter unit might turn itself off, based on the power management configuration. |
Blade blade_number is not allowed to power on because
of insufficient power. where blade_number identifies the blade server. |
There is insufficient power available in the power domain to turn on this blade server. |
Blade blade_number is throttled. where blade_number identifies the blade server. |
The specified blade server has reduced power (power throttling) in response to a thermal event or oversubscription condition. |
Blade blade_number was instructed to power off due
to power budget restrictions. where blade_number identifies the blade server. |
BladeCenter power management turns off a blade server that is already on in response to a oversubscription condition. |
Blade must be powered on to enable/disable dps. | The user attempts to enable or disable dynamic power server mode for a blade server while its power is off. |
Checking if power is preallocated to switch number failed. where the number I/O-module bay number. |
An error occurs while the management module is checking if power is preallocated for the specified I/O module. |
Demand exceeds a single power module. Throttling can occur
in power domain domain_number. where domain_number identifies the power domain. |
The power requirements of components installed in a power domain exceed the level required for redundant operation. Power throttling of BladeCenter components might be able to correct the problem. |
Effective CPU Speed not available. | An error occurs while the management module is reading the effective CPU Speed. |
Error reading blade power management capability. | An error occurs while the management module is reading the blade server power management capability. |
Error reading soft minimum. | An error occurs while the management module is reading the soft minimum value. |
Error reading soft minimum, using guaranteed minimum instead. | An error occurs while the management module is reading the soft minimum value. |
Error writing data for the option -pme Please make sure the blade is powered on |
The user attempts to enable power management and capping for a blade server that is turned off. |
Getting blade health state parameters failed. | An error occurs while the management module is reading the blade server health state parameters. |
Getting blade pcap maximum value failed. | An error occurs while the management module is reading the blade server power cap maximum value. |
Getting blade pcap minimum value failed. | An error occurs while the management module is reading the blade server power cap minimum value. |
Getting blade power cap level failed. | An error occurs while the management module is reading the blade server power cap level. |
Getting data of domain 1 (or 2 ) failed. | An error occurs while the management module is reading the data of power domain 1 (or 2). |
Getting domain latest power sample failed. | An error occurs while the management module is reading the latest power domain sample. |
Getting duty cycle numbers failed. | An error occurs while the management module is reading the duty cycle numbers. |
Getting duty cycle numbers of blade blade_number failed. where blade_number identifies the blade server. |
An error occurs while the management module is reading the duty cycle numbers of specified blade server. |
Getting dynamic power management capabilty of bladeblade_number failed. where blade_number identifies the blade server. |
An error occurs while the management module is reading the dynamic power management capability of specified blade server. |
Getting information of powernumber failed. where the number identifies the specified power module. |
An error occurs while the management module is reading data of specified power module. |
Getting module domain map for blowernumber failed. where the number identifies the specified chassis cooling unit. |
An error occurs while the management module is reading module domain map of specified chassis cooling unit. |
Getting module domain map for midplane failed. | An error occurs while the management module is reading the module domain map for midplane. |
Getting module domain map for MMnumber failed. where the number identifies the specified management module. |
An error occurs while the management module is reading the module domain map of specified management module. |
Getting module domain map for muxnumber failed. where the number identifies the location of the component. |
An error occurs while the management module is reading the module domain map of specified mux. |
Getting module domain map for NCnumber failed. where the number identifies the location of the component. |
An error occurs while the management module is reading the module domain map of specified network clock module. |
Getting module domain map of mtnumber failed. where the number identifies the specified mt. |
An error occurs while the management module is reading the module domain map of specified mt. |
Getting module domain map of PM Cooling Device number failed. where number identifies the blade server. |
An error occurs while the management module is reading the module domain map of specified power module Cooling Device. |
Getting module domain map of switchnumber failed. where the number represents the specified I/O module. |
An error occurs while the management module is reading the module domain map of specified I/O module. |
Getting module domain map of Telco alarm panel failed. | An error occurs while the management module is reading the module domain map of Telco alarm panel. |
Getting power management policy for domain domain_number
failed where domain_number is the number of the domain that was entered. |
An error occurs while the management module is reading the power management policy of specified domain. |
Getting power state of bladeblade_number failed. where blade_number identifies the blade server. |
An error occurs while the management module is reading the power state of specified blade server. |
Getting power values for blowernumber failed. where the number identifies the location of the component. |
An error occurs while the management module is reading the power values of specified chassis cooling unit. |
Getting power values for DSSnumber failed. where the number represents the specified DSS. |
An error occurs while the management module is reading the power values of specified DSS. |
Getting power values for MMnumber failed. where the number identifies the location of the component. |
An error occurs while the management module is reading the power values of specified management module. |
Getting power values for NCnumber failed. where the number represents the specified NC. |
An error occurs while the management module is reading the power values of specified network clock module. |
Getting power values for switchnumber failed.
where the number represents the specified I/O module. |
An error occurs while the management module is reading the power values of specified I/O module. |
Getting power values of midplane within domain failed. | An error occurs while the management module is reading the power values of midplane within domain. |
Getting power values of mtnumber within
domain failed. where the number represents the specified mt. |
An error occurs while the management module is reading the power values within domain of specified media tray. |
Getting power values of muxnumber within
domain failed. where the number represents the specified mux. |
An error occurs while the management module is reading the power values within domain of specified mux. |
Getting power values of PM Cooling Device number failed where the number represents the specified PM cooling device. |
An error occurs while the management module is reading the power values of specified power module cooling device. |
Getting power values of Telco alarm panel within domain failed. | An error occurs while the management module is reading the power values of Telco alarm panel within domain. |
Getting status of domain domain_number failed where domain_number identifies the power domain. |
An error occurs while the management module is reading the status of specified domain. |
Getting the power control setting on blade failed. | An error occurs while the management module is reading the power control setting on blade server. |
Invalid option for this blade: option
where option identifies the unacceptable option. |
The user attempts to issue a command with an option which is invalid for the targeted blade server. |
Maximum CPU Speed not available. | An error occurs while the management module is reading maximum CPU Speed. |
pcap must be between min and max Watts. where min and max represent the minimum and maximum wattage values permitted. |
The user input for power cap is out of the range. |
Power value is not in the guaranteed capping range. | The user attempts to set a power value that is out of range. |
Setting -e to nebs automatically disables -am, so "-am on" will be ignored. | The user attempts to set the environment to nebs and to enable the acoustic mode at the same time. |
There are mismatched power modules in power domain domain_number.
where domain_number identifies the power domain. |
The power modules installed in a power domain have different ratings. |
There is no thermal trending data to display. | An error occurs while the management module is reading thermal trending data. |
There is no trending data to display. | An error occurs while the management module is reading power trending data. |
Unable to change power management settings, domain may be oversubscribed. | An error occurs while the management module is configuring the power management policy. |