fuelg command errors

This topic lists error messages for the fuelg command.

See Common errors for a list of error messages that apply to all commands.

Table 1. fuelg command errors
Error message Definition
-am cannot be enabled while -e is set to nebs. The user attempts to enable the acoustic mode while the environment is set to nebs.
-ps and -dps cannot be enabled at the same time. The user attempts to enable -ps and idps at the same time.
A power module failure in domain domain_number can result in an immediate shutdown.

where domain_number identifies the power domain.

A power module fails and the domain in which it is installed loses redundancy. The BladeCenter unit might turn itself off, based on the power management configuration.
Blade blade_number is not allowed to power on because of insufficient power.

where blade_number identifies the blade server.

There is insufficient power available in the power domain to turn on this blade server.
Blade blade_number is throttled.

where blade_number identifies the blade server.

The specified blade server has reduced power (power throttling) in response to a thermal event or oversubscription condition.
Blade blade_number was instructed to power off due to power budget restrictions.

where blade_number identifies the blade server.

BladeCenter power management turns off a blade server that is already on in response to a oversubscription condition.
Blade must be powered on to enable/disable dps. The user attempts to enable or disable dynamic power server mode for a blade server while its power is off.
Checking if power is preallocated to switch number failed.

where the number I/O-module bay number.

An error occurs while the management module is checking if power is preallocated for the specified I/O module.
Demand exceeds a single power module. Throttling can occur in power domain domain_number.

where domain_number identifies the power domain.

The power requirements of components installed in a power domain exceed the level required for redundant operation. Power throttling of BladeCenter components might be able to correct the problem.
Effective CPU Speed not available. An error occurs while the management module is reading the effective CPU Speed.
Error reading blade power management capability. An error occurs while the management module is reading the blade server power management capability.
Error reading soft minimum. An error occurs while the management module is reading the soft minimum value.
Error reading soft minimum, using guaranteed minimum instead. An error occurs while the management module is reading the soft minimum value.
Error writing data for the option -pme

Please make sure the blade is powered on

The user attempts to enable power management and capping for a blade server that is turned off.
Getting blade health state parameters failed. An error occurs while the management module is reading the blade server health state parameters.
Getting blade pcap maximum value failed. An error occurs while the management module is reading the blade server power cap maximum value.
Getting blade pcap minimum value failed. An error occurs while the management module is reading the blade server power cap minimum value.
Getting blade power cap level failed. An error occurs while the management module is reading the blade server power cap level.
Getting data of domain 1 (or 2 ) failed. An error occurs while the management module is reading the data of power domain 1 (or 2).
Getting domain latest power sample failed. An error occurs while the management module is reading the latest power domain sample.
Getting duty cycle numbers failed. An error occurs while the management module is reading the duty cycle numbers.
Getting duty cycle numbers of blade blade_number failed.

where blade_number identifies the blade server.

An error occurs while the management module is reading the duty cycle numbers of specified blade server.
Getting dynamic power management capabilty of bladeblade_number failed.

where blade_number identifies the blade server.

An error occurs while the management module is reading the dynamic power management capability of specified blade server.
Getting information of powernumber failed.

where the number identifies the specified power module.

An error occurs while the management module is reading data of specified power module.
Getting module domain map for blowernumber failed.

where the number identifies the specified chassis cooling unit.

An error occurs while the management module is reading module domain map of specified chassis cooling unit.
Getting module domain map for midplane failed. An error occurs while the management module is reading the module domain map for midplane.
Getting module domain map for MMnumber failed.

where the number identifies the specified management module.

An error occurs while the management module is reading the module domain map of specified management module.
Getting module domain map for muxnumber failed.

where the number identifies the location of the component.

An error occurs while the management module is reading the module domain map of specified mux.
Getting module domain map for NCnumber failed.

where the number identifies the location of the component.

An error occurs while the management module is reading the module domain map of specified network clock module.
Getting module domain map of mtnumber failed.

where the number identifies the specified mt.

An error occurs while the management module is reading the module domain map of specified mt.
Getting module domain map of PM Cooling Device number failed.

where number identifies the blade server.

An error occurs while the management module is reading the module domain map of specified power module Cooling Device.
Getting module domain map of switchnumber failed.

where the number represents the specified I/O module.

An error occurs while the management module is reading the module domain map of specified I/O module.
Getting module domain map of Telco alarm panel failed. An error occurs while the management module is reading the module domain map of Telco alarm panel.
Getting power management policy for domain domain_number failed

where domain_number is the number of the domain that was entered.

An error occurs while the management module is reading the power management policy of specified domain.
Getting power state of bladeblade_number failed.

where blade_number identifies the blade server.

An error occurs while the management module is reading the power state of specified blade server.
Getting power values for blowernumber failed.

where the number identifies the location of the component.

An error occurs while the management module is reading the power values of specified chassis cooling unit.
Getting power values for DSSnumber failed.

where the number represents the specified DSS.

An error occurs while the management module is reading the power values of specified DSS.
Getting power values for MMnumber failed.

where the number identifies the location of the component.

An error occurs while the management module is reading the power values of specified management module.
Getting power values for NCnumber failed.

where the number represents the specified NC.

An error occurs while the management module is reading the power values of specified network clock module.
Getting power values for switchnumber failed.

where the number represents the specified I/O module.

An error occurs while the management module is reading the power values of specified I/O module.
Getting power values of midplane within domain failed. An error occurs while the management module is reading the power values of midplane within domain.
Getting power values of mtnumber within domain failed.

where the number represents the specified mt.

An error occurs while the management module is reading the power values within domain of specified media tray.
Getting power values of muxnumber within domain failed.

where the number represents the specified mux.

An error occurs while the management module is reading the power values within domain of specified mux.
Getting power values of PM Cooling Device number failed

where the number represents the specified PM cooling device.

An error occurs while the management module is reading the power values of specified power module cooling device.
Getting power values of Telco alarm panel within domain failed. An error occurs while the management module is reading the power values of Telco alarm panel within domain.
Getting status of domain domain_number failed

where domain_number identifies the power domain.

An error occurs while the management module is reading the status of specified domain.
Getting the power control setting on blade failed. An error occurs while the management module is reading the power control setting on blade server.
Invalid option for this blade: option

where option identifies the unacceptable option.

The user attempts to issue a command with an option which is invalid for the targeted blade server.
Maximum CPU Speed not available. An error occurs while the management module is reading maximum CPU Speed.
pcap must be between min and max Watts.

where min and max represent the minimum and maximum wattage values permitted.

The user input for power cap is out of the range.
Power value is not in the guaranteed capping range. The user attempts to set a power value that is out of range.
Setting -e to nebs automatically disables -am, so "-am on" will be ignored. The user attempts to set the environment to nebs and to enable the acoustic mode at the same time.
There are mismatched power modules in power domain domain_number.

where domain_number identifies the power domain.

The power modules installed in a power domain have different ratings.
There is no thermal trending data to display. An error occurs while the management module is reading thermal trending data.
There is no trending data to display. An error occurs while the management module is reading power trending data.
Unable to change power management settings, domain may be oversubscribed. An error occurs while the management module is configuring the power management policy.