You must configure the management module for command-line interface operation.
You configure only the primary (active) management module. The standby (redundant) management module, if present, receives the configuration and status information automatically from the primary management module when necessary. The configuration information in this topic applies to the primary management module, which might be the only management module in the BladeCenter® unit.
If the management module that you installed is a replacement for the only management module in the BladeCenter unit and you saved the configuration file before you replaced the management module, you can apply the saved configuration file to the replacement management module. For advanced management modules, see read command for information about applying a saved configuration file.
For the primary management module to communicate, you must configure the IP address for the external Ethernet (remote management) port (eth0) of the management module. The initial automatic management module configuration enables a remote console to connect to the management module to configure the port completely and to configure the rest of the BladeCenter unit.
After you connect the primary management module to the network, the Ethernet port connection is configured in one of the following ways. Either of these actions enables the Ethernet connection on the primary management module.
To configure the management-module Ethernet ports, complete the following steps: