monalerts command

This command displays and configures alerts that are monitored by the advanced management module.

Important: The monalertsleg command is no longer supported by the advanced management module firmware. Legacy alert monitoring that uses the monalertsleg command must transition to use of the monalerts command. Existing legacy alert settings are automatically mapped to the new alert categories as part of the transition.
Table 1. monalerts command
Function What it does Command Valid targets
Display monitored alert states Displays the state of all alerts being monitored by the management module. monalerts
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set state for enhanced legacy alert categories Enables enhanced legacy alert categories.
  • If enhanced legacy alert categories are enabled, alerts are configured using the monalerts command.
  • If enhanced legacy alert categories can not be disabled once they have been enabled.
monalerts -ec state

where state is enabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for all critical alerts Enables or disables monitoring of all critical alerts. monalerts -ca state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for blade device critical alerts Enables or disables monitoring of blade device critical alerts. monalerts -cb state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for I/O-module critical alerts Enables or disables monitoring of I/O-module critical alerts. monalerts -ciom state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for storage-module critical alerts

(BladeCenter S units only)

Enables or disables monitoring of storage-module critical alerts. monalerts -cstg state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for chassis or system management critical alerts Enables or disables monitoring of chassis or system management critical alerts. monalerts -ccsm state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for cooling device critical alerts Enables or disables monitoring of cooling device critical alerts. monalerts -ccd state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for power module critical alerts Enables or disables monitoring of power module critical alerts. monalerts -cpm state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for all warning alerts Enables or disables monitoring of all warning alerts. monalerts -wa state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for blade device warning alerts Enables or disables monitoring of blade device warning alerts. monalerts -wb state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for I/O-module warning alerts Enables or disables monitoring of I/O-module warning alerts. monalerts -wiom state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for storage-module warning alerts

(BladeCenter S units only)

Enables or disables monitoring of storage-module warning alerts. monalerts -wstg state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for chassis or system management warning alerts Enables or disables monitoring of chassis or system management warning alerts. monalerts -wcsm state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for event log warning alerts Enables or disables monitoring of event log warning alerts. monalerts -wel state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for cooling device warning alerts Enables or disables monitoring of cooling device warning alerts. monalerts -wcd state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for power module warning alerts Enables or disables monitoring of power module warning alerts. monalerts -wpm state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for all informational alerts Enables or disables monitoring of all informational alerts. monalerts -ia state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for blade device informational alerts Enables or disables monitoring of blade device informational alerts. monalerts -ib state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for I/O-module informational alerts Enables or disables monitoring of I/O-module informational alerts. monalerts -iiom state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for storage-module informational alerts

(BladeCenter S units only)

Enables or disables monitoring of storage-module informational alerts. monalerts -istg state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for chassis or system management informational alerts Enables or disables monitoring of chassis or system management informational alerts. monalerts -icsm state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for power state informational alerts Enables or disables monitoring of power state (on/off) informational alerts. monalerts -ipon state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for inventory change informational alerts Enables or disables monitoring of inventory change (installed components) informational alerts. monalerts -iinv state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for event log informational alerts Enables or disables monitoring of event log informational alerts. monalerts -iel state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for network change informational alerts Enables or disables monitoring of network change informational alerts. monalerts -inc state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for user activity informational alerts Enables or disables monitoring of user activity informational alerts. monalerts -iua state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for cooling device informational alerts Enables or disables monitoring of cooling device informational alerts. monalerts -icd state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Set monitoring state for power module informational alerts Enables or disables monitoring of power module informational alerts. monalerts -ipm state

where state is enabled or disabled.

This command can only be run by users who have one or more of the following command authorities:
  • Supervisor
  • Chassis configuration
See Commands and user authority for additional information.
                           -T system:mm[x]
                        

where x is the primary management-module bay number.

Example: To enable monitoring of all critical alerts and event log warning alerts and disable monitoring of all informational alerts, while management module 1 is set as the persistent command environment, at the system:mm[1]> prompt, type
                  monalerts -ca enabled -wel enabled -ia disabled
               

The following example shows the information that is returned from this command:

               system:mm[1]> monalerts -ca enabled -wel enabled -ia disabled
OK
system:mm[1]>