This command displays and configures alerts that are monitored by the advanced management module.
Function | What it does | Command | Valid targets |
---|---|---|---|
Display monitored alert states | Displays the state of all alerts being monitored by the management module. | monalerts |
where x is the primary management-module bay number. |
Set state for enhanced legacy alert categories | Enables enhanced legacy alert categories.
|
monalerts
-ec
state
where state is enabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for all critical alerts | Enables or disables monitoring of all critical alerts. |
monalerts
-ca
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for blade device critical alerts | Enables or disables monitoring of blade device critical alerts. |
monalerts
-cb
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for I/O-module critical alerts | Enables or disables monitoring of I/O-module critical alerts. |
monalerts
-ciom
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for storage-module
critical alerts
(BladeCenter S units only) |
Enables or disables monitoring of storage-module critical alerts. |
monalerts
-cstg
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for chassis or system management critical alerts | Enables or disables monitoring of chassis or system management critical alerts. |
monalerts
-ccsm
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for cooling device critical alerts | Enables or disables monitoring of cooling device critical alerts. |
monalerts
-ccd
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for power module critical alerts | Enables or disables monitoring of power module critical alerts. |
monalerts
-cpm
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for all warning alerts | Enables or disables monitoring of all warning alerts. |
monalerts
-wa
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for blade device warning alerts | Enables or disables monitoring of blade device warning alerts. |
monalerts
-wb
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for I/O-module warning alerts | Enables or disables monitoring of I/O-module warning alerts. |
monalerts
-wiom
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for storage-module
warning alerts
(BladeCenter S units only) |
Enables or disables monitoring of storage-module warning alerts. |
monalerts
-wstg
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for chassis or system management warning alerts | Enables or disables monitoring of chassis or system management warning alerts. |
monalerts
-wcsm
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for event log warning alerts | Enables or disables monitoring of event log warning alerts. |
monalerts
-wel
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for cooling device warning alerts | Enables or disables monitoring of cooling device warning alerts. |
monalerts
-wcd
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for power module warning alerts | Enables or disables monitoring of power module warning alerts. |
monalerts
-wpm
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for all informational alerts | Enables or disables monitoring of all informational alerts. |
monalerts
-ia
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for blade device informational alerts | Enables or disables monitoring of blade device informational alerts. |
monalerts
-ib
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for I/O-module informational alerts | Enables or disables monitoring of I/O-module informational alerts. |
monalerts
-iiom
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for storage-module
informational alerts
(BladeCenter S units only) |
Enables or disables monitoring of storage-module informational alerts. |
monalerts
-istg
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for chassis or system management informational alerts | Enables or disables monitoring of chassis or system management informational alerts. |
monalerts
-icsm
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for power state informational alerts | Enables or disables monitoring of power state (on/off) informational alerts. |
monalerts
-ipon
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for inventory change informational alerts | Enables or disables monitoring of inventory change (installed components) informational alerts. |
monalerts
-iinv
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for event log informational alerts | Enables or disables monitoring of event log informational alerts. |
monalerts
-iel
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for network change informational alerts | Enables or disables monitoring of network change informational alerts. |
monalerts
-inc
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for user activity informational alerts | Enables or disables monitoring of user activity informational alerts. |
monalerts
-iua
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for cooling device informational alerts | Enables or disables monitoring of cooling device informational alerts. |
monalerts
-icd
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
Set monitoring state for power module informational alerts | Enables or disables monitoring of power module informational alerts. |
monalerts
-ipm
state
where state is enabled or disabled. This command can only be run by users who have one or more
of the following command authorities:
|
where x is the primary management-module bay number. |
monalerts -ca enabled -wel enabled -ia disabled
The following example shows the information that is returned from this command:
system:mm[1]> monalerts -ca enabled -wel enabled -ia disabled
OK