This topic lists error messages for the read command.
See Common errors for a list of error messages that apply to all commands.
Error message | Definition |
---|---|
Both the -i and -l options must be specified with the -config file. | The user does not specify both the -i and -l options when restoring configuration from a file. |
Configuration restore from the chassis failed: i2c bus read error. | An error occurs while the management module is restoring the management module configuration from the BladeCenter unit midplane due to an i2c read error. |
Configuration restore from the chassis failed: operation not supported. | An error occurs while the management module is restoring the management module configuration from the BladeCenter unit midplane due to a failed system check. |
Configuration restore from the chassis failed: NVRAM compression error. | An error occurs while the management module is restoring the management module configuration from the BladeCenter unit midplane due to an EEPROM compression error. |
Configuration restore from the chassis failed: unsupported midplane data format. | An error occurs while the management module is restoring the management module configuration from the BladeCenter unit midplane due to an unsupported EEPROM format. |
Could not retrieve encryption data from the configuration file successfully. | The user tries to enter a passphrase that does not match the one that was used to create the backup configuration file. |
Error writing autoread flag. | An error occurs while the management module is writing autoread flag. |
File transfer failed. | An error occurs while transferring a file during file upload. |
Firmware update is in progress. Try again later. | The user tries to restore the management module configuration from the BladeCenter unit midplane while the management module firmware is updating. |
Please make sure you enter the correct passphrase for this configuration file. | The user tries to enter a passphrase that does not match the one that was used to create the backup configuration file. |
Resource allocation failure! Memory allocation failed for configuration read. | An error occurs while the management module is allocating memory. |
The -auto option can only be used with the -config chassis. | The user tries to set the -auto option when restoring the configuration from a file. |
The -config option and a config source is required. | The user tries to issue a command to read configuration from a file without specifying both the -config option and config source. |
The -config option is required. | The user does not include a required -config option for the command. |
The -i, -l, and -p options can only be used with the -config file. | The user tries to specify a TFTP server and a configuration file when restoring the configuration from the BladeCenter unit midplane. |
The passphrase is greater than 1600 characters. | The user tries to input a passphrase that exceeds the maximum length. |
The passphrase must be quote-delimited. | The user tries to input a passphrase that is not quote-delimited. |
There was a problem retrieving the file. | TFTP encounters an error when transferring the configuration file. |
Update Failed, there was a problem retrieving the file. | An error occurs while the advanced management module is uploading a file. |