0x00015500
Failed to change service processor management network interface

Explanation

The external interface of the management network for the blade server cannot be set.

Severity

Warning

Alert Category

Chassis/System Management (Warning) - mmTrapChassisN

Log Source

SERVPROC

Automatically notify service

No

Recoverable

No

Example Message

Failed to change service processor management network interface 1 configuration of blade 2.

Alarm Panel LED (BC T and BC HT)

Minor

User response

Perform these steps:
  1. Attempt to set the management network configuration for the blade server again.
  2. Reset the service processor on the blade server.
  3. Reseat the blade server.
  4. Update the firmware for the service processor on the blade server. You can find firmware on the IBM BladeCenter software and device drivers Web page.