0x00015600
Firmware update of Standby Management Module

Explanation

When the primary advanced management module completes a firmware update or a standby advanced management module is installed, the firmware for the standby will be updated if it is different than the firmware level of the primary. The firmware update of the standby advanced management module failed.

Severity

Warning

Alert Category

Chassis/System Management (Warning) - mmTrapChassisN

Log Source

SERVPROC

Automatically notify service

No

Recoverable

No

Example Message

Firmware update of Standby Management Module from MM 1 to MM 2 failed.

Alarm Panel LED (BC T and BC HT)

Minor

User response

Restart the primary advanced management module. When the primary advanced management module is restarted, it will determine that the firmware levels are different and will attempt to update the firmware again.
If the primary advanced management module fails over to the standby (making it the primary) and the firmware levels are different, the new primary advanced management module will attempt to update the previous primary advanced management module to the active firmware level.
Note: The background update of the standby advanced management module can upgrade to newer or older firmware levels.