Explanation
When the primary advanced management module completes a firmware update or a standby advanced management
module is installed, the firmware for the standby will be updated if it is different
than the firmware level of the primary. The firmware update of the standby advanced management module failed.
Severity
Warning
Alert Category
Chassis/System Management (Warning)
-
mmTrapChassisN
Log Source
SERVPROC
Automatically notify service
No
Recoverable
No
Example Message
Firmware update of Standby Management Module from MM 1 to MM 2 failed.
Alarm Panel LED (BC T and BC HT)
Minor
User response
Restart the primary advanced management module.
When the primary advanced management module is restarted, it will determine that the firmware levels are different and will attempt
to update the firmware again.
If the primary advanced management module fails over to the standby (making it the primary) and the firmware levels are different,
the new primary advanced management module will attempt to update the previous primary advanced management module to the active firmware level.