Chassis type detection failure.
Explanation
The chassis type detected by the advanced management module is not valid. Therefore, the advanced management module will substitute a new chassis type value and attempt to restart.
Do not change the configuration until the advanced management module has restarted.
Severity
Error
Alert Category
Chassis/System Management (Critical)
-
mmTrapChassisC
Log Source
SERVPROC
Automatically notify service
No
Recoverable
Yes
Example Message
Chassis type detection failure. The AMM will override current chassis type BC-1 with BC-H for recovery before reboot.
Chassis LED
Error
Alarm Panel LED (BC T and BC HT)
Critical
User response
The advanced management module will override the chassis type and restart automatically to resolve the issue.
While the advanced management module is restarting, do not change the hardware configuration.
Continue to monitor the event log to determine if the situation occurs again.
If so, reseat the advanced management module.