0x00015801
Chassis type detection failure.

Explanation

The chassis type detected by the advanced management module is not valid. Therefore, the advanced management module will substitute a new chassis type value and attempt to restart. Do not change the configuration until the advanced management module has restarted.

Severity

Error

Alert Category

Chassis/System Management (Critical) - mmTrapChassisC

Log Source

SERVPROC

Automatically notify service

No

Recoverable

Yes

Example Message

Chassis type detection failure. The AMM will override current chassis type BC-1 with BC-H for recovery before reboot.

Chassis LED

Error

Alarm Panel LED (BC T and BC HT)

Critical

User response

The advanced management module will override the chassis type and restart automatically to resolve the issue. While the advanced management module is restarting, do not change the hardware configuration.