0x0001D502
Chassis over recommended ambient temperature.

Explanation

The current chassis temperature is above the recommended ambient temperature for this chassis.

Severity

Warning

Alert Category

Chassis/System Management (Warning) - mmTrapChassisN

Log Source

SERVPROC

Automatically notify service

No

Recoverable

Yes

Chassis LED

Error, Temperature

Alarm Panel LED (BC T and BC HT)

Minor

User response

Perform these steps:
  1. Check the room ambient temperature to ensure that it is within the operating specifications for the chassis.
  2. Make sure that all fan/blower modules are running. Replace fan modules if necessary.
  3. Make sure that a device or filler is installed in each bay in the front and rear of the chassis, and make sure that there is nothing covering the bays. Any missing components can cause a major reduction in airflow for the blade server.
  4. Make sure that there is nothing covering the media tray (that will disrupt the airflow to the ambient temperature sensor).
  5. Replace the media tray.