Primary MM local management bus failed.
Explanation
An internal management bus on the primary advanced management module has failed.
Severity
Error
Alert Category
Chassis/System Management (Critical)
-
mmTrapChassisC
Log Source
SERVPROC
Automatically notify service
Yes
Recoverable
Yes
Chassis LED
Error
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- Restart the advanced management module.
- Flash (update if applicable) the firmware for the advanced management module and
restart the advanced management module.
- Fail over to the standby advanced management module if available.
Then reseat the advanced management module that had the error.
Fail back to see if error persists. If a standby advanced management module is not present, reseat
the advanced management module.
- Replace the failed advanced management module.