Primary MM Ethernet port 0 failed.
Explanation
Ethernet port 0 on the primary advanced management module has failed.
Severity
Error
Alert Category
Chassis/System Management (Critical)
-
mmTrapChassisC
Log Source
SERVPROC
Automatically notify service
No
Recoverable
Yes
Chassis LED
Error
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- Check the event log for a recovery message. If present, no action is required.
- Restart the advanced management module.
- Flash (update if applicable) the firmware for the advanced management module and restart the advanced management
module.
- Fail over to the standby advanced management module if available. Then reseat the advanced management module that had the error.
Fail back to see if error persists. If the standby advanced management module is not present, reseat
the advanced management module.