Standby MM ethernet port 0 failed.
Explanation
Ethernet port 0 on the standby advanced management module has failed during built in self test (BIST).
Severity
Warning
Alert Category
Chassis/System Management (Warning)
-
mmTrapChassisN
Log Source
SERVPROC
Automatically notify service
No
Recoverable
Yes
Chassis LED
Error
Alarm Panel LED (BC T and BC HT)
Minor
User response
Perform these steps:
- Check the Ethernet connection from the
standby advanced management module (the one without the active light at the back of the chassis) to ensure
that the Ethernet connection is functional.
- Make sure the Ethernet cable is properly seated at both ends.
- Try another Ethernet cable.
- Make sure the Ethernet switch at the other end is active and working (try another port or other switch).
- Generate a manual call home using Service Advisor.