Standby MM backup core failed.
Explanation
The backup core on the standby advanced management module failed during built-in self test (BIST).
This event is typically caused by an issue with the firmware image itself. Reloading the firmware image will normally correct the situation.
Severity
Warning
Alert Category
Chassis/System Management (Warning)
-
mmTrapChassisN
Log Source
SERVPROC
Automatically notify service
No
Recoverable
Yes
Chassis LED
Error
Alarm Panel LED (BC T and BC HT)
Minor
User response
Perform these steps at your earliest convenience:
- Restart the primary advanced management module.
- Restart the standby advanced management module.
- Initiate a failover to the standby advanced management module and either reload the advanced management module
firmware or update the firmware to the latest level.
- Reseat the advanced management module.
- Reload or update the advanced management module firmware again.
- Generate a manual call home using Service Advisor to replace the advanced management module.