Primary MM USB mass storage firmware failed.
Explanation
The primary advanced management module mass storage firmware update on the primary advanced management module has failed because the advanced management module could not access the firmware storage.
Severity
Warning
Alert Category
Chassis/System Management (Warning)
-
mmTrapChassisN
Log Source
SERVPROC
Automatically notify service
No
Recoverable
Yes
Chassis LED
Error
Alarm Panel LED (BC T and BC HT)
Minor
User response
Verify that the remote drive is still functioning correctly. If so, no action is required.
If the remote drive is not functioning correctly, perform these steps:
- Restart the advanced management module.
- Update the firmware for the advanced management module. After updating the firmware, you will need to
restart the advanced management module.
- Reseat the advanced management module.
- Generate a manual call home using Service Advisor to replace the advanced management module.