Primary MM internal I/O expander failed.
Explanation
The internal I/O Expander on the primary advanced management module failed during built-in self test (BIST).
Severity
Error
Alert Category
Chassis/System Management (Critical)
-
mmTrapChassisC
Log Source
SERVPROC
Automatically notify service
Yes
Recoverable
Yes
Chassis LED
Error
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform this steps:
- Restart the advanced management module.
- Flash (update if applicable) the firmware for the advanced management module and
restart the advanced management module.
- Fail over to the standby advanced management module if available. Then reseat the advanced management
module that had the error. Fail back to see if the error persists. If the standby advanced management module
is not present, reseat the advanced management module.
- Replace the failed advanced management module.