Chassis Cooling Device 03 failure.
Explanation
The specified fan or blower module is no longer operating.
Severity
Error
Alert Category
Cooling Devices (Critical)
-
mmTrapFanC
Log Source
Cool_##
Automatically notify service
Yes
Recoverable
Yes
Chassis LED
Error
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- Check to make sure that the rear fan or blower module is receiving power. To do this, check the System Status page
through
the advanced management module Web interface.
Note: The BladeCenter T chassis has an illuminated green power LED when
power is present. An amber LED indicates lack of power or a failed component.
- Check your power source and cabling.
Note: All power cords must be attached.
- Reseat the fan or blower module.
- Replace the fan or blower module.