0x00028000
Power fault

Explanation

The specified blade server has encountered a power fault.

Severity

Error

Alert Category

Power Modules (Critical) - mmTrapPsC

Log Source

Blade_##

Automatically notify service

Yes

Recoverable

Yes

Chassis LED

Error

Alarm Panel LED (BC T and BC HT)

Critical

User response

Perform these steps:
  1. Check the event log to see if this is happening on multiple blades. If so, suspect the power module. See the IBM Support Web page for service bulletins related to troubleshooting power issues.
  2. If this is happening for a single blade server:
    1. Update the systems management firmware (BMC) for the blade server through the advanced management module Web interface.
    2. Reseat the blade server.
    3. Replace the system board (trained service technician only).