0x000A2003
Chassis Cooling Device 3 communication failed.

Explanation

A communication error occurred between the advanced management module and the fan or blower module in fan bay 3.

Severity

Error

Alert Category

Chassis/System Management (Critical) - mmTrapChassisC

Log Source

SERVPROC

Automatically notify service

Yes

Recoverable

Yes

Chassis LED

Error

Alarm Panel LED (BC T and BC HT)

Critical

User response

Perform these steps:
  1. Examine the event log. Communication problems on the I2C management bus can cause this error as well as a failed fan or blower module. Actions for bus issues include restarting the advanced management module, failing over to a standby advanced management module, and reseating the components on the bus, including the advanced management module and blower or fan modules.
  2. Replace the fan or blower module.