Chassis Cooling Device 3 communication failed.
Explanation
A communication error occurred between the advanced management module and the fan or blower module in fan bay 3.
Severity
Error
Alert Category
Chassis/System Management (Critical)
-
mmTrapChassisC
Log Source
SERVPROC
Automatically notify service
Yes
Recoverable
Yes
Chassis LED
Error
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- Examine the event log. Communication problems on the I2C management bus can cause
this error as well as a failed fan or blower module. Actions for bus issues include restarting the
advanced management module,
failing over to a standby advanced management module, and reseating the components on the bus,
including the advanced management module and blower or fan modules.
- Replace the fan or blower module.