One or more blades are isolated from the management bus.
Explanation
The advanced management module was not able to communicate with one or more blade servers, so it isolated those blade servers
from the management bus.
Severity
Warning
Alert Category
Chassis/System Management (Warning)
-
mmTrapChassisN
Log Source
SERVPROC
Automatically notify service
No
Recoverable
No
Alarm Panel LED (BC T and BC HT)
Minor
User response
Perform these steps:
- View the System Status Summary page through the advanced management module Web interface to determine which blade servers have been isolated.
- Attempt to reset the service processor for each of the blade servers. You can reset the service processor through the advanced management module Web interface from the
Blade Power/Restart page.
- Reseat each of the blade servers.