Explanation
The advanced management module encountered a failure on system management bus.
A failover was initiated and the advanced management module is now the standby advanced management module.
Severity
Error
Alert Category
Chassis/System Management (Critical)
-
mmTrapChassisC
Log Source
SERVPROC
Automatically notify service
No
Recoverable
Yes
Chassis LED
Error
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- At your earliest convenience, initiate a failover to make the advanced management module
the primary advanced management module. This will reset the advanced management module.
- Verify that the advanced management module can communicate with other components in the chassis.
- If it cannot
communicate with other any devices, perform these steps:
- Reset the advanced management module.
- Replace the advanced management module.
- If it can communicate with other devices, go to the built-in self test (BIST) results from the AMM Status page of the advanced management
module Web interface to determine which component may be causing a problem.