Multi Processor Expansion board fault.
Explanation
A fault has occurred in the Multiprocessor Expansion Unit for the specified blade server.
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
Blade_##
Automatically notify service
Yes
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- Flash (update if applicable) the firmware for the service processor (BMC), BIOS, and firmware for the advanced management module.
- Reseat the Multiprocessor Expansion Unit.
- Remove all components in the Multiprocessor Expansion Unit. Then add the components back in, one at a time. Restart
the blade server each time to see if the issue has been corrected.
- Replace the following components one at a time, in the order shown, restarting the blade server each time:
- Multiprocessor Expansion Unit
- Base system board assembly (trained service technician only)
Refer to the Problem Determination and Service Guide for the specified blade server type
for information about the Multiprocessor Expansion Unit. The Problem Determination and Service Guide is available on the Web.