Explanation
The specified CPU on the specified blade server has been disabled.
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
Blade_##
Automatically notify service
No
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Major
User response
Perform these steps:
- Restart the service processor for the specified blade server. You can restart the service processor from the advanced management module Web interface.
- Reboot the blade server and press F1 to display the BIOS menu:
- Verify that both processors are being seen by BIOS.
- Load the default settings.
- Go to the advanced setup menu, select the CPU settings, and attempt to re-enable the CPU slot.
- Swap processors on the blade server to determine if the problem is related to the CPU slot or the processor.