I/O board power fault.
Explanation
A fault has occurred in the I/O expansion blade.
Severity
Warning
Alert Category
Blades (Warning)
-
mmTrapBladeN
Log Source
Blade_##
Automatically notify service
Yes
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Minor
User response
Perform these steps:
- If voltage problem are occurring on multiple blade servers, look for other events in the event log related to power and resolve those events.
Note: If voltage problems are occurring on multiple blade servers in the same power domain,
the problem might be in one of the power modules that power that domain (log in to the advanced management module to see the power modules that are associated with each power domain).
Therefore, Replace the power modules, one at a time, to see if the problem is resolved.
- Reseat the I/O-expansion blade.
- Replace the following components one at a time, in the order shown, restarting the blade server each time:
- I/O-expansion blade
- System board assembly (trained service technician only)
Refer to the Problem Determination and Service Guide for the specified blade server type
for information about removing and installing components. The Problem Determination and Service Guide is available on the Web.