System shutoff due to DASD Option temperature.
Explanation
The service processor on the specified blade server has
shut down because the Direct Access Storage Device (DASD) has reached or exceeded the over-temperature threshold.
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
SERVPROC
Automatically notify service
No
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- Check the room ambient temperature to ensure that it is within the operating specifications for the chassis.
- Make sure that all fan/blower modules are running. Replace fan modules if necessary.
- Make sure that a device or filler is installed in each bay in the front and rear of the chassis, and make sure that there is nothing covering the bays. Any missing components can cause a major reduction in airflow for the blade server.