0x06A2E002
Chassis temperature device is unavailable. Cooling capacity set to maximum.

Explanation

The chassis temperature is unavailable or unreadable from any media tray. The cooling capacity for the chassis has been set to the maximum, and the fan modules are running at full speed.

Severity

Warning

Alert Category

Chassis/System Management (Warning) - mmTrapChassisN

Log Source

SERVPROC

Automatically notify service

No

Recoverable

Yes

Chassis LED

Error

Alarm Panel LED (BC T and BC HT)

Minor

User response

Check the event log for communication failures for multiple components, such as I/O modules, fan modules, and power modules. If there are communication failures for multiple components, restart the advanced management module.
If there are no other communication failures, perform these steps:
  1. Reseat the media tray.
  2. Replace the media tray.