0x09025000
Front panel cable is not connected to system board

Explanation

The connection between the front bezel on the blade and the system board has become loose or damaged. The buttons on the front bezel will not be useable and the LEDs will not light.

Severity

Warning

Alert Category

Blades (Warning) - mmTrapBladeN

Log Source

Blade_##

Automatically notify service

No

Recoverable

Yes

Alarm Panel LED (BC T and BC HT)

Minor

User response

Perform these steps:
  1. Reseat the control panel cable.
  2. Replace the following components one at a time, in the order shown, restart the blade server each time:
    1. Bezel assembly
    2. System board assembly (trained service technician only)

Refer to the Problem Determination and Service Guide for the specified blade server type for information about replacing components. The Problem Determination and Service Guide is available on the Web.