Concurrent KVM card fault detected.
Explanation
A fault has occurred for the concurrent KVM keyboard/video/mouse (cKVM) feature card in the specified blade server.
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
Blade_##
Automatically notify service
Yes
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- Check the change history on the Web for firmware updates that may be related to this problem, including
cKVM, BIOS, and advanced management module firmware. Update the firmware if applicable.
- Reseat the cKVM feature card.
- Replace the Concurrent KVM feature card.
Refer to the Problem Determination and Service Guide for the specified blade server type
for information about removing and installing a cKVM feature card. The Problem Determination and Service Guide is available on the Web.