Explanation
An uncorrectable memory error has occurred for the specified blade server.
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
Blade_##
Automatically notify service
Yes
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- Check the IBM Support Web page for related service bulletins.
- Check the blade server BIOS change history on the Web for any memory related fixes. Update the BIOS if applicable.
- Use Light Path diagnostics to verify the affected DIMM bank.
- Record the DIMM part number and size for future reference.
Note: For some blade servers, the DIMM part number is available through the advanced management module Web interface.
- Verify that the memory DIMM is supported on the IBM ServerProven Web site.
- Check to make sure the DIMMs are seated properly (especially if this is a new installation). If the DIMMs required reseating,
boot the blade into BIOS setup and enable the memory bank.
- Replace the DIMMs in the memory bank, boot the blade server to BIOS setup and enable the memory bank.