0x0A000402
Correctable memory error logging limit reached on DIMM 02

Explanation

The correctable memory error logging threshold for the specified blade server was reached.

Severity

Error

Alert Category

Blades (Critical) - mmTrapBladeC

Log Source

Blade_##

Automatically notify service

Yes

Recoverable

Yes

Alarm Panel LED (BC T and BC HT)

Critical

User response

At your earliest convenience, perform these steps:
  1. Update the service processor firmware and BIOS for the blade server.
  2. Reseat the memory DIMM. Take note of the DIMM part number and size for future reference.
  3. Re-enable the memory bank in BIOS. Boot the blade server to BIOS and re-enable the memory bank.
  4. Replace the memory DIMM. Refer to the Problem Determination and Service Guide for the specified blade server type for information about replacing memory. The Problem Determination and Service Guide is available on the Web.