Explanation
The correctable memory error logging threshold for the specified blade server was reached.
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
Blade_##
Automatically notify service
Yes
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Critical
User response
At your earliest convenience, perform
these steps:
- Update the service processor firmware and BIOS for the blade server.
- Reseat the memory DIMM. Take note of the DIMM part number and size for future reference.
- Re-enable the memory bank in BIOS. Boot the blade server to BIOS and re-enable the memory bank.
- Replace the memory DIMM. Refer to the Problem Determination and Service Guide for the specified blade server type
for information about replacing memory. The Problem Determination and Service Guide is available on the Web.