Explanation
The specified DIMM for the specified blade server has been disabled. This is a result of a previous uncorrectable memory error.
Severity
Error
Alert Category
Blades (Critical)
-
mmTrapBladeC
Log Source
Blade_##
Automatically notify service
No
Recoverable
Yes
Example Message
Memory device 01 (DIMM 01 Status) memory disabled
Alarm Panel LED (BC T and BC HT)
Critical
User response
This error generally follows another memory error. If you already performed the
actions for the previous uncorrectable memory error, no additional action is required. If not, perform these steps:
- Check the IBM Support Web page for related service bulletins.
- Check the blade server BIOS change history on the Web for any memory related fixes. Update the BIOS if applicable.
- Use Light Path diagnostics to verify the affected DIMM bank.
- Record the DIMM part number and size for future reference.
Note: For some blade servers, the DIMM part number is available through the advanced management module Web interface.
- Verify that the memory DIMM is supported on the IBM ServerProven Web site.
- Check to make sure the DIMMs are seated properly (especially if this is a new installation). If the DIMMs required reseating,
boot the blade into BIOS setup and enable the memory bank.
- Replace the DIMMs in the memory bank, boot the blade server to BIOS setup and enable the memory bank.