0x0E006008
Blade 08 incompatible with I/O module configuration

Explanation

The fabric type of an expansion card option in the specified blade server is not compatible with an I/O module in the I/O module bay. Data might not be passed on one or more possible connections.

Severity

Warning

Alert Category

Blades (Warning) - mmTrapBladeN

Log Source

Blade_##

Automatically notify service

No

Recoverable

Yes

Alarm Panel LED (BC T and BC HT)

Minor

User response

Verify that the network is set up as desired. To verify the network configuration from the advanced management module Web interface, click Blades and then click I/O compatibility. If the network configuration is correct, no action is required. Otherwise, make sure that the fabric type of the expansion card option in the specified blade server is compatible with the fabric type of the I/O module.