0x0E00B001
I/O module 01 is not allowed to power on due to insufficient power.

Explanation

The management module has detected that there is not sufficient power capacity in the power budget to allow the specified I/O module to power on.

Severity

Error

Alert Category

Chassis/System Management (Critical) - mmTrapChassisC

Log Source

IOMod_##

Automatically notify service

No

Recoverable

Yes

Chassis LED

Error

Alarm Panel LED (BC T and BC HT)

Critical

User response

Perform these steps:
  1. Select a different power management policy to increase the power budget.
  2. Add additional power modules or upgrade the power modules to increase power capacity.
  3. Reseat the blade server.
  4. Shut down other devices in the chassis.