0x0EA0D405
Change port link state on I/O Module 05 failed

Explanation

The port link state for the specified I/O module was not changed.

Severity

Warning

Alert Category

I/O Modules (Warning) - mmTrapION

Log Source

IOMod_##

Automatically notify service

No

Recoverable

No

Alarm Panel LED (BC T and BC HT)

Minor

User response

Perform these steps:
  1. Check the user permissions to ensure that the user has the authority to change the port state. See the Advanced Management Module User's Guide for more information about user roles.
  2. Attempt to change the port link state again.
  3. Check the event log for other errors related to the I/O module (such as communication errors between the advanced management module and the I/O module).
  4. Check the advanced management module system status panel to ensure the switch is functioning.