0x0EA0E006
I/O module 06 POST failure

Explanation

The specified I/O module has encountered a problem during power on self test (POST).

Severity

Error

Alert Category

I/O Modules (Critical) - mmTrapIOC

Log Source

IOMod_##

Automatically notify service

No

Recoverable

Yes

Chassis LED

Error

Alarm Panel LED (BC T and BC HT)

Major

User response

Perform these steps:
  1. Power off the I/O module and attempt to start it again from the Admin Power Restart page of the advanced management module Web interface.
  2. Reseat the I/O module.
  3. Refer to the documentation for the specified I/O module. The documentation for the specified switch might contain additional information about this problem.
  4. Replace the I/O module.