A hard disk drive PFA condition on Storage Module 1 was detected.
Explanation
A Predictive Failure Analysis (PFA) alert has been received for a hard disk drive in the specified storage module.
Severity
Warning
Alert Category
Storage Modules (Warning)
-
mmTrapStorageN
Log Source
Stor_##
Automatically notify service
Yes
Recoverable
Yes
Alarm Panel LED (BC T and BC HT)
Minor
User response
Perform these steps:
- Log in to the SAS RAID controller either through Storage Configuration Manager* or through the command-line interface (CLI) to determine which hard drive has caused the PFA condition. *Storage Configuration Manager is not supported when configured with 12 disks storage module.
- At your earliest convenience, replace the hard disk drive.
See the IBM BladeCenter SAS RAID Controller Module Installation and User's Guide for information about PFA conditions and replacing hard disk drives. The guide is available from the Web.