0x0EA0E401
A hard disk drive PFA condition on Storage Module 2 was detected.

Explanation

A Predictive Failure Analysis (PFA) alert has been received for a hard disk drive in the specified storage module.

Severity

Warning

Alert Category

Storage Modules (Warning) - mmTrapStorageN

Log Source

Stor_##

Automatically notify service

Yes

Recoverable

Yes

Alarm Panel LED (BC T and BC HT)

Minor

User response

Perform these steps:
  1. Log in to the SAS RAID controller either through Storage Configuration Manager* or through the command-line interface (CLI) to determine which hard drive has caused the PFA condition. *Storage Configuration Manager is not supported when configured with 12 disks storage module.
  2. At your earliest convenience, replace the hard disk drive.

See the IBM BladeCenter SAS RAID Controller Module Installation and User's Guide for information about PFA conditions and replacing hard disk drives. The guide is available from the Web.