Explanation
The temperature for the specified I/O module has exceeded the fault threshold.
Severity
Error
Alert Category
I/O Modules (Critical)
-
mmTrapIOC
Log Source
IOMod_##
Automatically notify service
No
Recoverable
Yes
Chassis LED
Error, Temperature
Alarm Panel LED (BC T and BC HT)
Critical
User response
Perform these steps:
- Make sure the fan modules are working properly.
- Make sure the ambient temperature is within the operating requirements for the chassis.
- Make sure that a device or filler is installed in each bay in the front and rear of the chassis, and make sure that there is nothing covering the bays.
- Check to see if there is a firmware update for the advanced management module that is related to over temperature conditions. If so, update the firmware for the advanced management module.
- Update the firmware for the I/O module.
- Replace the I/O module.