0x0EA1D405
I/O module 05 over recommended temperature

Explanation

The temperature for the specified I/O module exceeds the recommended temperature.

Severity

Warning

Alert Category

I/O Modules (Warning) - mmTrapION

Log Source

IOMod_##

Automatically notify service

No

Recoverable

Yes

Chassis LED

Error, Temperature

Alarm Panel LED (BC T and BC HT)

Minor

User response

Perform these steps:
  1. Check the room temperature to ensure that it is within the operating specifications for the chassis.
  2. Make sure that all fan/blower modules are running. Replace fan modules if necessary.
  3. Make sure that a device or filler is installed in each bay in the front and rear of the chassis, and make sure that there is nothing covering the bays. Any missing components can cause a major reduction in airflow for the blade server.
  4. Make sure that there is nothing covering the chassis (that will obstruct airflow through the chassis).