Explanation
The temperature for the specified I/O module exceeds the recommended temperature.
Severity
Warning
Alert Category
I/O Modules (Warning)
-
mmTrapION
Log Source
IOMod_##
Automatically notify service
No
Recoverable
Yes
Chassis LED
Error, Temperature
Alarm Panel LED (BC T and BC HT)
Minor
User response
Perform these steps:
- Check the room temperature to ensure that it is within the operating specifications for the chassis.
- Make sure that all fan/blower modules are running. Replace fan modules if necessary.
- Make sure that a device or filler is installed in each bay in the front and rear of the chassis, and make sure that there is nothing covering the bays. Any missing components can cause a major reduction in airflow for the blade server.
- Make sure that there is nothing covering the chassis (that will obstruct airflow through the chassis).